Self-supporting towers are all triangular tubular towers made out of hot dip galvanized steel, to be assembled by means of bolts and nuts.
|
ORYX |
|
Deflection: +/- 1°
Towers here enclosed have been designed for a 5m² antenna load.
Antenna loading Capacities: from 4 to 6m²
Tower especially designed for mobile telephony with small bottom dimensions and internal ladder
Oryx/Some samples of Oryx tower range.
Nominal Height (m) |
Basic Wind Speed |
- |
160 Km/h |
200 Km/h |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
|
|
12 |
15 |
20 |
25 |
30 |
35 |
40 |
|
|
|
|
|
ORION-R |
|
Deflection: +/- 1°
Towers here enclosed have been designed for a 10m² antenna load.
Antenna loading Capacities: from 6 to 10m²
Tower with internal ladder for two operators uses .
Some samples of Orion-R tower range.
|
Basic Wind Speed |
Hauteur Nominale /
Nominal Height (m) |
|
8 |
|
10 |
|
12 |
|
15 |
|
20 |
|
25 |
|
30 |
|
35 |
|
40 |
|
45 |
|
50 |
|
55 |
|
60 |
|
|
|
|
|
|
OMEGA |
|
Deflection: +/- 20'
Towers here enclosed have been designed for a 10m² antenna load.
Antenna loading Capacities: from 8 to 20m²
Tower especially designed for heavy antenna loading and small deflection value.Oryx/Some samples of
Some samples of Omega tower range.
Nominal Height (m) |
Basic Wind Speed |
- |
|
8 |
|
10 |
|
12 |
|
15 |
|
20 |
|
25 |
|
30 |
|
35 |
|
40 |
|
45 |
|
50 |
|
55 |
|
60 |
|
70 |
|
80 |
|
90 |
|
|
|
|
|
|
PAT-91 |
|
Deflection: +/- 45'
Towers here enclosed have been designed for a 40m² antenna load.
Antenna loading Capacities: 20m² and more
Tower especially designed for heavy antenna loading and small deflection value and important heights.
Some samples of Pat-91 towers
Nominal Height (m) |
Basic Wind Speed |
- |
|
20 |
|
25 |
|
30 |
|
35 |
|
40 |
|
45 |
|
50 |
|
55 |
|
60 |
|
70 |
|
80 |
|
90 |
|
100 |
|
120 |
|
|
|
|
|
|
ALPHA |
|
Deflection: +/- 1°
Towers here enclosed have been designed for a 14m² antenna load.
Antenna loading Capacities: from 5 to 15m²
Tower with internal ladder for several operators uses .
Some samples of Alpha towers.
Nominal Height (m) |
Basic Wind Speed |
- |
|
8 |
|
12 |
|
15 |
|
20 |
|
25 |
|
30 |
|
35 |
|
40 |
|
45 |
|
50 |
|
55 |
|
60 |
|
|
|
|
|
|
ALPHA |
|
Deflection: +/- 20'
Towers here enclosed have been designed for a 23m² antenna load.
Antenna loading Capacities: from 15 to 25m²
Tower especially designed for heavy antenna loading and small deflection value.
Some samples of Helix towers.
Nominal Height (m) |
Basic Wind Speed |
- |
|
15 |
|
20 |
|
25 |
|
30 |
|
35 |
|
40 |
|
45 |
|
50 |
|
55 |
|
60 |
|
|
|
|
|